Wednesday 21 September 2016

Development Length Calculation as per Indian Code

Development length is the extra length of bar provided beyond the required section in order to ensure the following;
  • To develop a safe bond between the bar surface & the concrete so that no failure due to slippage of bar occurs during the ultimate load conditions.
  • Also, the extra length of the bar provided as development length is responsible for transferring the stresses developed in any section to the adjoining sections (such as at column beam junction the extra length of bars provided from beam to column).
Importance: Provision of appropriate development is an important aspect of safe construction practices, proper development length in reinf. bars shall be provided as per the steel grade considered in design otherwise in scenarios where less development length against the required is provided the structures will be prone to encounter  failure due to slippage of joints, bonds, anchors & Laps, in such cases the bars will not yield first but the failure will happen at joints & laps prior to yielding of reinforcement bars.

Calculation of Development length:
As per the Indian Standard – IS 456: 2000, clause 26.2.1 the development length Ld is given the following expression;

 Where,             Ø            = nominal dia of reinforcement bar
 σs               = Stress in bar at the section considered at design load
 τbd           = Design bond stress
The above given formula is used to calculate the required development length in mm for any given dia of bar, same formula is used for limit state method as well as working stress method. The only change in calculation in both methods is due to the different value of design bond stress; the values of design bond for Limit State & working stress are as follows;


Design Bond Stress in Limit State Method
Concrete Grade
M20
M25
M30
M35
M40 & Above

Design Bond Stress (τbd, N/mm2)
1.2
1.4
1.5
1.7
1.9
For Plain Bars in Tension
1.92
2.24
2.4
2.72
3.04
For deformed bars in tension
**Note: For bars in compression 1.25 times the above-given values shall be used.
              

Design Bond Stress in Working Stress Method
Concrete Grade
M20
M25
M30
M35
M40
M45
M50

Design Bond Stress (τbd, N/mm2)
0.8
0.9
1.0
1.1
1.2
1.3
1.4
For Plain Bars in tension
1.28
1.44
1.6
1.76
1.92
2.08
2.24
For deformed bars in tension
**Note: For bars in compression 1.25 times the above given values shall be used.
            

Generally, in practice, the development length requirement is expressed as ‘41 times Ø’ or ‘41 Ø’ where 41 is the factor calculated using the above formula & Ø is the dia of the bar.
Example: In the following images, calculation for development length in limit state method (Fig.1), as well as working stress method (Fig.2) for M25 concrete grade & 415 steel grade, are illustrated;

Fig-1 (For Limit State Method)

Fig-2 (For Working Stress Method)
-----^^^-----




suggestions/comments may be sent to alok.dixit009@gmail.com


73 comments:

  1. simply superb....really nice explanation and example problmes reallyy easy to understand

    ReplyDelete
  2. Very good to explain the Development length formulas,
    Really I like it!!!
    Thanks

    ReplyDelete
  3. This question creat Very big problem for me but now its very easy for this explanation thank you so much

    ReplyDelete
  4. Can someone please give the table of shear stress in bar in working stress method

    ReplyDelete
    Replies
    1. SORRY BUT I DIDN'T GET YOUR QUESTION EXACTLY, REGARDING SHEAR WHEN THE NOMINAL SHEAR STRESS IN ANY GIVEN BEAM SECTION GOES BEYOND THE MAXIMUM PERMISSIBLE SHEAR STRESS VALUE OF CONCRETE SECTION RELEVANT TO AREA OF CROSS-SECTION OF BEAM & Ast PROVIDED THEN SHEAR REINFORCEMENT IS REQUIRED TO BE PROVIDED. ALSO MINIMUM SHEAR REINFORCEMENT IS MANDATORY FOR PROVISION AS PER IS 456.
      KINDLY REFER ANNEX-B SECTION B-5 OF IS 456: 2000 FOR FURTHER CLARIFICATION REGARDING THE SAME.

      Delete
  5. u need to correct the value 415 to .87*fy

    ReplyDelete
    Replies
    1. THE FOS OF 1.15 (CL. 36.4.2.1, IS 456: 2000) AS MENTIONED IN YOUR COMMENT (AS 1/1.15=0.87) IS APPLICABLE FOR DESIGN OF STRUCTURES FOR LIMIT STATE OF COLLAPSE BUT GENERALLY, THE DESIGNS ARE CARRIED OUT WITHIN THE SERVICEABILITY RANGE SO THAT THE STRUCTURE DOES NOT FAIL SUDDENLY BUT INDICATIVE SIGNS WOULD BE EXHIBITED PRIOR TO FAILURE AFTER THE SERVICE RANGE IS CROSSED. THEREFORE FURTHER REDUCTION IN STEEL STRESS IS NOT REQUIRED ALSO IF YOU WILL DECREASE THE STEEL STRESS FURTHER BY USING 0.87 FOS THE VALUE OF DEVELOPMENT LENGTH WILL FURTHER DECREASE WHICH WE WILL HELP YOU IN ACHIEVING THE ECONOMY BUT NOT THE SAFETY. THUS IT IS RECOMMENDED TO USE FE 415/500/550 VALUES ONLY.

      Delete
    2. It's very useful and helpful to me
      Thanks for your information

      Delete
  6. This is the basic formula and explanation mentioned in IS 456, but we don't read it. Rather we prefer to read on internet.

    ReplyDelete
    Replies
    1. THANKS FOR YOUR COMMENT SIR, AS WE ALL ARE LITTLE LESS ACQUAINTED TO IS CODES AT SOME STAGE IN OUR CAREER & EDUCATION THUS THE SAME HAS BEEN REPRODUCED HERE ALONG WITH THE EXPLANATION FOR THE SAME. REFERENCES OF THE CODES ARE ALSO MENTIONED HERE IN THE POST. THE POINT YOU HAVE RAISED IS QUITE VALID & I ALSO SUPPORT YOU WE ALL SHOULD REFER OUR TEXTS & STANDARDS AS A ROUTINE.

      Delete
  7. It's useful and easily explained

    Thank you

    ReplyDelete
  8. sir, how to overcome by the error " the valve of e for member N does not seem to be realistic"
    thank you

    ReplyDelete
    Replies
    1. The above warning comes in STAAD Pro when you have assigned 'E' (modulus of elasticity) value to a material different from value of steel & then steel code is used for design of the members. In such cases STAAD suggests to check the value of modulus of elasticity for the material.

      Delete
  9. Sir, But is this formula use full for all the structural member like beams,columns,footings,ext..are the same ?

    ReplyDelete
    Replies
    1. Yes this is the same formula for calculation of Ld.

      Delete
  10. I think two examples are wrong because putting value is wrong. Please verify it according to IS:456

    ReplyDelete
    Replies
    1. The values used in the given examples are correct but as you can see in yield stress of steel bars i have not used reduction factor of 0.87 because by upon using the Ld value will be reduced & thus it is not recommended.

      Delete

  11. Thank you very much for the info agan convey and hopefully useful to my friend who read it.
    Click Here : farm tractors for sale 260-60 HP TURBO

    ReplyDelete
  12. For designing of bond stress in limit state method, is bond stress value of 1.9 is enough for the grade M40 and above? why so ? since grade of concrete increases, bond stress also increases. Why can't we provide value greater than 1.9 for M40 and above, say for M80? Why IS has certain prescription ?

    ReplyDelete
  13. What will be the stress for Fe 500/ Fe 550 bar in working stress method ?

    ReplyDelete
  14. Sir in limit state method
    Design bond stress is your wrong.as per IS code
    Is M25 mixed concrete 1.4 N/mm2

    ReplyDelete
  15. For limit state method what is the value of bond stress for fe500 steel??
    Is it 500???

    ReplyDelete
  16. Check for development length along which direction should be considered?

    ReplyDelete
  17. How to find sigma s if not mentioned on drawing

    ReplyDelete
  18. Hi sir,
    Length of bolt length required=tension/(pi*dia*bond stress) ....i want derivation ?

    please urgent

    ReplyDelete
  19. now a day which method is use in construction limit state or working state which one is suitable and why

    ReplyDelete
  20. this length you have calculated 552mm provide both end side or half of both side of the beam section

    ReplyDelete
  21. formula sigmab Y = 0.87Fy/4jbd

    ReplyDelete
  22. why there is a factor of 1.25 fro compression compared to that of tension?

    ReplyDelete
  23. why there is a factor of 1.25 for compression compared to that of tension?

    ReplyDelete
  24. Very informative post. Development length calculation of steel,You can also know ms steel suppliers in chennai offers a best standard and used for various purposes. The quality steels will be used in a wide range. jsw steel dealers in Chennai also earn the customers trust in the same way like ms steel.

    ReplyDelete
  25. If the concrete grade of the column and beam is different, what concrete grade will follow for the development length of the beam at the column beam junction?

    ReplyDelete
  26. Amazing post, thank you for sharing this knowledgeable post, really this is very helpful.Development Length Calculation

    ReplyDelete
  27. then where we use this development length formula

    (0.87fyDia/4Tbd)

    ReplyDelete
  28. should we consider a multiplier for bond stress of steel? That is for Fe500 grade steel should we multiply by 0.87 while calculating the development length. Because in most of the material they have used it.

    ReplyDelete
  29. I am eldin
    It was very helpful

    ReplyDelete
  30. What about the lapping length?

    ReplyDelete
  31. What about development length in compression?

    ReplyDelete
  32. Hi there, yeah this post is genuinely nice and I have learned a lot of things from it concerning blogging. thanks.

    Bathroom Mirrors

    ReplyDelete
  33. Sheet metal forming processes :Sheet metal framing processes are those wherein power is applied to a piece of sheet metal to adjust its calculation as opposed to eliminating any material

    ReplyDelete
  34. 4 CNC Drehmaschine kaufen will make a perfect machien for devlopment

    ReplyDelete
  35. what is carbonmax toe i really don't knwo can you please tell me ??

    ReplyDelete